Advanced MPPT maximum power point tracking technology, the tracking efficiency is no less than 99.5%.
High quality components are used to improve the system performance, and the maximum conversion efficiency can reach 97%.
Super fast maximum power tracking speed while ensuring tracking efficiency.
Accurate identification and tracking of the maximum power point of multi-wave peak.
Reliable maximum input power of pv array to ensure the safety of equipment.
Wide pv array maximum power point operating voltage range.
12/24v automatic voltage identificationThe LCD is designed to dynamically display the operation data and working status of the equipment.
Various load control modes: general mode, light control mode, dual time mode, pure charger mode and timing mode.
Seal, GEL, Flooded, LifePO4 and Li(NiCoMn)O2 charging process can be selected.
The function of battery temperature compensation.
Power statistics recording function.
Use the RS485methods to maximize the communication needs ofSupport PC monitor, external display unit and other peripherals, realize real-time data view and parameter setting function.
Item |
RG-CN 10A |
RG-CN20A |
RG-CN30A |
RG-CN50A |
RG-CN60A |
rated charge current |
10A |
20A |
30A |
50A |
60A |
dimension |
175*118*40mm |
96*133*54.5mm |
270*195*70mm |
||
Battery voltage |
12/24V auto work |
||||
Max PV input power |
12v-130W |
12v-260W |
12v-390W |
12v-650W |
12v-780W |
|
24v-260W |
24v-520W |
24v-780W |
24v-1300W |
24v-1560W |
duration of absorption charging |
2hours |
||||
protection class |
IP30 |
||||
Charge mode |
MPPT |
||||
LCD temperature |
-20℃~+70℃ |
||||
storege temperature |
-30℃~+80℃ |
||||
Operating temperature |
-20℃~+55℃(to run at full rated current continuously) |
||||
Temp,compensation |
-4mV/℃(25℃) |
||||
Battery type |
User default, Sealed, Flooded, GEL, LiFePO4 |
||||
Equalized charging voltage |
Maintenance-fee lead acid battery 14.6V, GEL: No; Lead acid flooded battery: 14.8V |
||||
Absorption charging voltage |
Maintenance-fee lead acid battery 14.4V, GEL: 14.2; Lead acid flooded battery: 14.6V |
||||
Floating charging voltage |
Maintenance-fee lead acid battery, GEL, Lead acid flooded battery: 13.8V |
||||
Low voltage re-connection (LVR) |
Maintenance-fee lead acid battery, GEL, Lead acid flooded battery: 12.6V |
||||
Low voltage disconnection (LVD) |
Maintenance-fee lead acid battery, GEL, Lead acid flooded battery: 10.8V |
||||
Working humidity |
≦95% No condensation |